Abstract
This study aims to estimate the critical fluid flow velocity for preventing the development of a stationary bed using empirical correlations valid for horizontal and highly inclined wellbores that can be easily used at the field. For this purpose, experiments have been conducted at METU-PETE Cuttings Transport Flow Loop for various conditions. Observations showed that a stationary bed is developed when the fuid velocity is less than 6.0 ft/s, and a critical fluid velocity of 8.0 ft/s is required to establish a no-bed condition. Results showed that the critical velocity and the thickness of the stationary bed, if developed, could be estimated with a reasonable accuracy.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.