Abstract

Flicker fields from 270 individuals between 6 and 95 years of age were grouped into nine age ranges, each covering a decade and containing 30 individuals. For each decade, mean critical flicker frequencies were computed for 49 points of the visual field situated on the horizontal, vertical, and oblique meridians from 0° to 60°. These were presented in nine tables of standard flicker frequencies. For each field point the confidence limits have been statistically determined and entered into the tables. These values should be applied in field plots to determine the boundary lines between retinal regions of normal and abnormal functions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.