Abstract

Critical curves have been calculated for the graphical determination of the magnetization direction as function of applied magnetic field in ion-implanted garnet films having cubic anisotropy. Up to three stable magnetization directions may exist when the applied field is inside the critical curves. This leads to the formation of charged walls. The hard magnetization directions are found to be favorable directions for charged walls and the easy magnetization directions are unfavorable. The complex domain-wall patterns revealed by Ferrofluid techniques in 1-μm magnetic bubble devices are explained by using the calculated critical curve. Futhermore, critical curves for several different symmetries have also calculated to correspond to different crystallographic orientations and garnet material parameters.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.