AbstractVarious methods for the evaluation of the critical J‐integral JIC based on the standard ASTM E813–89 are analyzed by conducting investigations on a ductile medical grade ultra high molecular weight polyethylene (UHMW‐PE) at room temperature. Differences in JIC reaching almost 50% were recorded between the methods investigated. The controversy surrounding the construction of the crack blunting line is discussed in terms of the stretch zone width together with the size requirements of ASTM E813–89. The findings of this investigation suggest that an R‐curve construction based on mid‐thickness crack growth and ultimate tensile strength (UTS) combined with a blunting line of slope m = 2 and modified exclusion lines provides consistent and conservative JIC values. Using this technique, a near plane strain value, smaller than previously published data, of 66.5 kJ/m2 was obtained at 23°C.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.