Abstract

Demagnetization of permanent magnet machines is a fault that evolves over time leading to an eventual catastrophic failure. This condition is of particular interest in renewables, with emphasis on remote applications such as offshore wind, tidal and wave energy harvesting. Moreover, the demagnetization fault can be either uniform or non-uniform. The strong majority of research papers are focusing on non-uniform demagnetization and typically study the case of a single faulty magnet. This is because, the uniform demagnetization does not create harmonics that can be detected with spectral methods. Despite the above, the study of single magnet demagnetization studies have been criticized due to being unrealistic to describe most practical cases where permanent magnet machines are subjected to demagnetization due to overloading and/or overheating conditions and leading to uniform demagnetization. This paper sheds some light into such theories, while studying a, realistically induced in the lab, demagnetization case of a direct-drive C-GEN permanent magnet generator.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.