Abstract

IntroductionTo identify patients with aneurysmal degeneration of the native aorta following type A aortic dissection (TAAD), reproducible serial measurements of aortic dimensions are critical. We used a systematic workflow for measuring aortic geometry following TAAD, using computed tomography angiography data, and test its reproducibility.MethodsThe workflow for aortic measurements included centerline generation, luminal diameter, and area measurement at six anatomically defined locations along the aorta and luminal volumetric measurements in the descending aorta. Two independent observers measured the aortic geometry in 20 surgically repaired TAAD patients, preoperatively and at 3 months follow‐up. To test reproducibility, intraobserver and interobserver agreement scores were analyzed using a concordance correlation coefficient (CCC).ResultsThe interobserver agreement scores of the diameter, area, and volumetric measurements in the descending aorta were acceptable. The agreement scores of the area measurements were highest, with CCCs ranging from 0.909 to 0.984. Luminal diameter measurements scored lower than luminal area measurements and were least reproducible at the mid aortic arch (CCC < 0.886). Overall, intraobserver agreement scores were better than interobserver agreement scores (SD of mean difference was 1.89 vs 1.94 for intraobserver vs interobserver diameter measurements, and 0.61 vs 0.66 for area measurements).ConclusionAlthough overall reproducibility was acceptable in descending aortic measurements, our results show that it remains challenging to reliably measure luminal diameters, compared with areas. To aid identification of early adverse remodeling following acute TAAD, novel two‐ and three‐dimensional measurement techniques are needed that capture locoregional changes in the false lumen and true lumen morphology more accurately.

Highlights

  • To identify patients with aneurysmal degeneration of the native aorta following type A aortic dissection (TAAD), reproducible serial measurements of aortic dimensions are critical

  • The results of the interobserver reproducibility analysis will be the focus of the remainder of this study, as the higher degree of interobserver variability will drive the overall reliability of our measurement workflow in a typical clinical situation

  • We summarize our results as follows: (1) In postoperative TAAD patients, all luminal area measurements are more reproducible than luminal diameter measurements

Read more

Summary

Introduction

To identify patients with aneurysmal degeneration of the native aorta following type A aortic dissection (TAAD), reproducible serial measurements of aortic dimensions are critical. We used a systematic workflow for measuring aortic geometry following TAAD, using computed tomography angiography data, and test its reproducibility. Intraobserver and interobserver agreement scores were analyzed using a concordance correlation coefficient (CCC). Results: The interobserver agreement scores of the diameter, area, and volumetric measurements in the descending aorta were acceptable. The agreement scores of the area measurements were highest, with CCCs ranging from 0.909 to 0.984. Luminal diameter measurements scored lower than luminal area measurements and were least reproducible at the mid aortic arch (CCC < 0.886). Conclusion: overall reproducibility was acceptable in descending aortic measurements, our results show that it remains challenging to reliably measure luminal diameters, compared with areas. To aid identification of early adverse remodeling following acute TAAD, novel two‐ and three‐dimensional measurement

Objectives
Methods
Results
Discussion
Conclusion