Abstract

ABSTRACT The shaft-loaded blister test (SLBT) was used to investigate the adhesion between a model epoxy coating and a silicon oxide surface as a function of relative humidity. Critical and subcritical strain energy release rates were measured using specimens that incorporate reinforcing layers of Kapton® film. A simplified procedure that eliminates the need for video imaging to measure the blister radius and fracture energy was developed. A critical relative humidity level for adhesion loss was observed, in agreement with measurements that have been made previously in a number of polymeric systems. The SLBT was confirmed to be particularly attractive for fracture energy measurements on thin, strongly adhered coatings and films which otherwise tend to be problematic.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.