Abstract
Despite the wide range of existing performance measures to evaluate functional status of patients with multiple sclerosis, the heterogeneous nature of the disease hinders clinical characterization and monitoring of disease severity. Speckle tracking ultrasonography is a non-invasive technique to assess isolated muscle function by evaluating the contractile properties of muscle tissue, i.e. muscle strain. The aim of this study was to investigate whether muscle strain measured by speckle tracking ultrasonography could be a useful quantitative measure of muscle function in patients with multiple sclerosis. The criterion validity of muscle strain was compared to that of validated performance measures of upper and lower extremity function. This cross-sectional study used baseline data from an explorative observational cohort study (the MUST study). Participants recruited from a hospital outpatient MS clinic underwent speckle tracking ultrasonography of the biceps brachii, supraspinatus, and soleus muscles of the dominant side according to pre-defined submaximal isometric contractions. Participants also completed the Timed 25-Foot Walk Test, the Six Spot Step Test, the 2-minute walking test, the Nine-Hole Peg Test, the 12-item Multiple Sclerosis Walking Scale, and the Oxford Shoulder Score. Gaussian distribution was investigated by visual inspection of normal probability plots and the Shapiro-Wilk test. The Timed 25-Foot Walk Test and Nine-Hole Peg Test were selected as gold standards for function of the lower and upper extremities, respectively. Criterion validity was assessed using Spearman's rank-order correlation coefficient ρ (rho), comparing the muscle strain and performance measures against predefined gold standards. Differences in criterion validity were estimated using squared correlations on the Fischer's Z-scale, with non-parametric bootstrapping to obtain bias-corrected, accelerated bootstrap confidence intervals (95% BCa). Criterion validity showed good to excellent correlations between the gold standard for lower extremity function and the 2-minute walking test and Six Spot Step Test, and a fair correlation to the 12-item Multiple Sclerosis Walking Scale. No significant correlation was found between the gold standard for upper extremity function and the performance measure. There were no significant correlations between the gold standards and muscle strain. The absence of criterion validity for muscle strain alongside fair to strong criterion validity for the performance measures indicates that speckle tracking ultrasonography assessment of muscle strain is either invalid or evaluates other constructs of multiple sclerosis. Muscle strain assessed by speckle tracking ultrasonography cannot be recommended for the evaluation of treatment effects or disease progression in multiple sclerosis.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.