Abstract

Elevator noise in apartments can make annoying sounds depending on locations of elevators and the sensitivity of the residents. Some nations have their own criteria regarding noise from elevators, however, South Korea has no such criteria, which makes it difficult to handle the damage due to noise from elevators. Thus, the present study investigated noise criteria in elevators in other nations and identified the noise characteristics during elevator operation to provide foundational data at the time of setup on noise criteria forelevators. The noise criteria in other nations recommend the maximum noise level to be below NC-20–30 and 25–30 dB(A). The noise measurement in elevators showed that the maximum noise level at the adjacent room was NC-29, 31.4 dB(A) in A Apartment, and NC-26~29, 30.8–32.7 dB(A) in B Apartment.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.