Abstract

There is no enough evidence present on the success of single implant-retained mandibular overdentures (SIMO) with Dalla Bona and Locator attachments. This study aims to compare crestal bone loss and patient satisfaction with SIMO with Dalla Bona and Locator attachment following immediate loading protocols. Twelve patients included in Group 1 received immediate SIMO with Dalla Bona attachments, and another twelve patients in Group 2 received immediate SIMO with Locator attachments in the mid symphyseal region. The follow-up was scheduled at 6 and 12 months after implant placement. The patient satisfaction with the denture was evaluated with the visual analog scale (VAS) score. The data obtained were statistically analyzed with the independent student t-test for intergroup comparison and repeated measures of ANOVA followed by Bonferroni's Post hoc analysis for intragroup comparison of mean crestal bone loss at a different time interval. Ten patients each in both the groups were available for follow-up. Crestal bone loss at 6 months follow-up for Dalla Bona group was 0.42 ± 0.10 mm on the mesial side and 0.43 ± 0.14 mm on the distal side and at 1 year 1.54 ± 0.16 mm on the mesial side and 1.66 ± 0.13 mm on the distal side. The mean crestal bone loss at 6 months follow-up for Locator group was 0.48 ± 0.16 mm on the mesial side and 0.45 ± 0.11 mm on the distal side and at 1 year was 1.71 ± 0.22 mm on mesial side and 1.74 ± 0.28 mm on the distal side. There was difference in bone loss at 6 months (mesial: 0.06 mm, p = 0.327; distal:0.02 mm; p = 0.726) and at 1 year (mesial: 0.17 mm, p = 0.063; distal: 0.08 mm; p = 0.423) in between two groups but the difference was statistically insignificant. There was a significant difference found in the VAS score for patient satisfaction with SIMO with Dalla Bona attachments and Locator attachments at 6 months (54.2 vs. 51.8, p = 0.005) and 1 year (60.6 vs. 55.2, p = 0.005). Patient satisfaction with SIMO with Dalla Bona attachments was higher during the follow-up. SIMO with Dalla Bona attachments had less crestal bone loss and less prosthetic complications when compared to Locator attachments, although the difference in the bone loss was statistically insignificant.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.