Abstract
Creep deflection can be an important consideration in the design of metal plate–connected (MPC) wood trusses. Chapter 2 of the ANSI/TPI 1-2007 truss standard, referenced by the 2009 International Building Code (IBC), defines the responsibility of the registered design professional when specifying MPC wood trusses. Based on Section 2.3.2.4 (h) of the standard, the registered design professional shall provide design criteria that addresses in-service creep deflection behavior of flat roofs subject to ponding loads and floor trusses supporting stone or ceramic tile finishes. In this paper, we review relevant standards and research studies on creep behavior of MPC wood trusses and offer a rational calculation method based on 10- and 15-year test data for estimating creep deflection for parallel chord MPC wood trusses. Examples are included to illustrate the calculation method for determining a design creep factor that is related to the sustained load percentage relative to total design load. Some practical wa...
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Practice Periodical on Structural Design and Construction
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.