Abstract

AbstractConventional process safety wisdom assumes that check valves are not reliable safeguards. Experience indicates that check valves are prone to failure and that they may fail undetected. Therefore, the conservative assumption is that check valves may be listed in process hazard analyses as safeguards, but they are rarely considered to meet the standards required of an independent protection layer (IPL). Independent protection layers must be effective, independent, and auditable. Although independence is readily achievable by check valves, confirming and routinely auditing effectiveness is rarely pursued. And maintenance practices for check valves are often insufficient. Little data is available from operating companies regarding failure and leakage rates for different check valve types in various service applications or at various stages of service life. This paper examines a testing protocol that was put in place in 2014 for the purpose of testing check valves in order to apply layer of protection analysis (LOPA) credit to these valves for reverse flow scenarios. In order to understand check valve performance expectations, leakage allowances for new check valves are reviewed. Industry guidance and standards regarding consideration of check valves as safeguards or IPLs are also discussed. The analysis of new valve standards and the assessment of process safety requirements are the basis for establishing the pass/fail thresholds for the tests. The goal of sharing this information is that the discussion will stimulate others to consider the opportunity and the need to set‐up similar testing and to begin gathering and sharing a larger body of data on check valve performance in various applications. Accumulation of check valve performance data and sharing of that data should lead to better understanding of check valve performance by type, size, age, and service. Better performance may be achieved where maintenance is improved and where learnings are applied to selection and design. In instances where requirements are met and credit is due, check valves may be credited in PHA and LOPA.1

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.