Abstract

This paper presented the results of a study on the cracking behavior of early age massive concrete with large-diameter pipes during construction. Material property tests were conducted to identify the time-dependent mechanical properties of the early age concrete made of P.O. 42.5 cement. A full-scale reinforced concrete block of 4.4×4.8×3m with pipes up to 508 mm in diameter was cast and monitored for the development of the temperature and strain of concrete. A three-dimensional FEM model was established based on user defined subroutine for the time-dependent mechanical and creep properties. The FEM model was verified based on the test results and was used for cracking risk analysis of massive concrete with different pipe layouts. It is found that a diameter to edge distance ratio or a diameter to spacing ratio of no more than 1/3 is sufficient to prevent additional cracking risk of concrete due to the presence of pipes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.