Abstract

Several methods have been proposed currently for evaluating the crack width of a mortar specimen. Among these, the water permeability test is widely used to estimate crack width because water permeability is directly related to the average crack width of a specimen through which water passes. However, the viscosity of water makes precise crack width measurement challenging. The possible inflow (outflow) of foreign (healing) substances could affect the test results. To circumvent this limitation, this study proposes a gas diffusion test using oxygen rather than water as the medium. The proposed method includes a process that could compensate for gas diffusion from specimen parts other than the crack, allowing for a more precise estimation of crack width. The crack width can indeed be estimated with an error of 4% or less.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.