Abstract

Ultrasonic fatigue tests were performed on Ti60 titanium alloy up to a very high cycle fatigue (VHCF) regime at various stress ratios to investigate the characteristics. The S-N curves showed continuous declining trends with fatigue limits of 400, 144 and 130 MPa at 109 cycles corresponding to stress ratios of R = −1, 0.1 and 0.3, respectively. Fatigue cracks found to be initiated from the subsurface of the specimens in the VHCF regime, especially at high stress ratios. Two modified fatigue life prediction models based on fatigue crack initiation mechanisms for Ti60 titanium alloy in the VHCF regime were developed which showed good agreement with the experimental data.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call