Abstract

Compression tests were carried out on UHV diffusion bonded single crystalline sapphire/Nb/sapphire joints to investigate their mechanical properties, the mechanisms that lead to the failure of the joints and the dislocation-interface interaction. The tests were performed for different orientation relationships (OR) at the interface to study the influence of different bond strength on the mechanical behavior. Additionally, the metal layer thickness was varied for each OR to alter the influence of the interface. The experimental results showed, that with decreasing metal layer thickness the stress needed to form a crack increases drastically, whereas for the Nb/sapphire system the bond strength at the interface seems to have no significant influence on the mechanical behavior of the joint. A theoretical model will be presented that explains the experimentally observed relationship between metal layer thickness and crack stress.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.