Abstract

Batch experiments were conducted to remove Cr(VI) from aqueous solution using activated sludge biomass. The effects of acid pretreatment of the biomass, initial pH, biomass and Cr(VI) concentrations on Cr(VI) removal efficiency were investigated. Proton consumption during the removal process and the reducing capacity of sludge biomass were studied. The results show that acid pretreatment could significantly improve Cr(VI) removal efficiency and increase Cr(VI) reducing capacity by 20.4%. Cr(VI) removal was remarkably pH-dependent; lower pH (pH = 1, 2) facilitated Cr(VI) reduction while higher pH (pH = 3, 4) favored sorption of the converted Cr(III). Lower Cr(VI) concentration as well as higher biomass concentration could accelerate Cr(VI) removal. Cr(VI) reduction was not the only reason for proton consumption in the removal process. Pseudo-second-order adsorption kinetic model could successfully simulate Cr(VI) removal except under higher pH conditions (pH = 3, 4).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.