Abstract

Over the last three years (2020-2022) Diamond Light Source has installed four in-house designed, built, and measured Cryogenic Permanent Magnet Undulators (CPMUs). All four are 2 m long with a 17.6 mm period and have a minimum operating gap of 4 mm. These have replaced existing 2 m long in-vacuum Pure Permanent Magnet (PPM) devices to improve the flux to several of Diamond’s MX (Macromolecular Crystallography) beamlines by a factor of 2-4. In this paper we present the mechanical and cryogenic design considerations, and the shimming procedures and tools developed to produce these devices. The performance of the CPMUs compared to their PPM counterparts will also be reviewed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.