Abstract

Covalent organic framework TpBD was grafted on stainless steel wire with polydopamine as a linker. The fabricated TpBD bonded stainless steel wire was used as the solid-phase microextraction fiber to extract sixteen polycyclic aromatic hydrocarbons (PAHs) for subsequent GC-MS/MS determination in grilled meat samples. The developed method gave the limits of detection (S/N = 3) from 0.02 (pyrene)-1.66 (naphthalene) ng L−1 and enhancement factors from 1069 (naphthalene)-10879 (benz(a)anthracene). The relative standard deviations (RSDs) for intra-day and inter-day study are in the range of 2.6%–8.5% and 4.5%–9.4%, respectively. The fiber-to-fiber RSDs for three parallel prepared fibers were 5.3%–10.0%. One TpBD bonded fiber can stand at least 200 cycles without significant loss of extraction efficiency. The developed method was successfully applied for the determination of trace PAHs in grilled meat samples with recoveries from 85.1% to 102.8%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.