Abstract

A novel label-free optical biosensing scheme by using a single mode coupled microcavity laser is experimentally realized. We demonstrate that a slight change of the coupling coefficient due to the existence of biosamples leads to sensitive single mode laser hopping to a new frequency that is several nm away from the original mode wavelength. By monitoring the emergence of the hopped laser mode intensity, the lowest detectable concentration of bovine serum albumin (BSA) of approximately 80 pg/mL was obtained, which is comparable to the detection limit of a passive microcavity sensor with Q > 10(7), but with a much simplified experimental setup. With the mode hopping and mode shift combined, the single frequency coupled cavity laser provides a detection range from pg/mL (limit of mode hopping) to microg/mL (limit of mode shift). Our results show the possibility of using a coupled optical microcavity to achieve ultrasensitive optical sensing.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.