Abstract

Analysis of organic compounds in aerosol particles using real-time single particle techniques is difficult because of extensive fragmentation that occurs in the laser desorption/ionization step. In an effort to avoid such fragmentation processes, we coupled a “soft” two-step laser desorption/ionization technique (L2MS) with aerosol time-of-flight mass spectrometry (ATOFMS). In these studies, we find this combination preserves intact organic molecules while providing the real-time mass spectra of suspended aerosol particles. Mass spectra of particles analyzed by one-step desorption mass spectrometry and L2MS are presented for comparison. These include 2,4-dihydroxybenzoic acid as a test case and wood and cigarette combustion particles as real world examples. This is the first published demonstration of L2MS performed on single particles not deposited on a substrate prior to analysis.