Abstract

A sensitive method has been established for the determination of the pyrethroids (fenpropathrin and permethrin) in water samples. It is based on microextraction using monoliths composed of a poly-(glycidyl methacrylate-co-ethylene dimethacrylate) copolymer, and on detection by gas chromatography coupled to electron-capture detection. Experimental parameters including the flow rate and volume of the samples, the type, volume and flow rate of eluent and effect of salt addition were optimized. The limits of detection for fenpropathrin and permethrin are 0.5 and 2.7 ng mL−1, respectively. The intra-day and inter-day precisions were less than 5.5% and 9.0%. The method was successfully applied to determination of two pyrethroids in the tap and lake water samples and the accuracy was evaluated by recovery experiments.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.