Abstract
The OHC drives cochlear amplification, and prestin activity is the basis. The frequency response of nonlinear capacitance (NLC), which is a ratiometric measure of prestin's voltage-sensor charge movement (dQp/dVm), depends on the location of AC voltage excitation along prestin's operating voltage range, being slowest at the voltage (Vh) where NLC peaks. Here we directly investigate the coupling between prestin charge movement (Qp) and electromotility (eM) at frequencies up to 6.25 kHz, and find tight correspondence between the two at operating voltages displaced from Vh. Near Vh, however, eM shows a slower frequency response than Qp. We reason that coupling is more susceptible to molecular/cellular loads at Vh, where prestin compliance is expected to be maximal. Recent cryo-EM studies have begun to shed light on structural features of prestin that impact its performance against loads.This article is part of the Special Issue Outer hair cell Edited by Joseph Santos-Sacchi and Kumar Navaratnam
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.