Abstract
Due to the limited space on the train, the shielded cables were utilized to protect signal cables against influence by the disturbance from power cables which arranged in parallel with the signal cables. To reduce cable coupling, the cables are usually arranged close to train body. The influence of the body of the train should not be ignored. To analyze the coupling of shielded cables in the train, a hybrid method is proposed based on the circuit model. To solve the influence from the reflection of the train body, Green's function deduced from image theory is utilized. The current on the shielding layer is calculated by lumped circuit model, which is set up by admittance parameter matrix. And then, the coupling voltage on the core of shielded cable is given by using BTL function. Finally, a laboratory test case and a field test were investigated. Results of the proposed method were validated by measurement results.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.