Abstract

AbstractA coupled simulation of the flue gas and process gas side of the convection section of a steam cracker is performed, making use of the CFD software package Fluent. A detailed overview of the operating mode of the different heat exchangers suspended in the convection section is obtained. The asymmetric inlet flow field of the flue gas in the convection section, and the radiation from the convection section walls leads to large differences in outlet temperatures of the tubes located in the same row. The flow fields and temperature fields in the tubes of a single heat exchanger differ significantly with e.g., outlet temperatures of the hydrocarbon‐steam mixture ranging from 820 K to 852 K. Moreover, the simulations reveal the presence of hot spots on the lowest tube row, possibly causing fouling. © 2009 American Institute of Chemical Engineers AIChE J, 2009

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.