Abstract
Neutronic performance of a coupled hydrogen moderator was studied as a function of para hydrogen concentration, moderator thickness and height, premoderator thickness, etc. for the J-PARC spallation neutron source. It was found that a thick ( 140 mm ) moderator with 100% para-hydrogen was optimal to provide a high time- and energy-integrated neutron intensity below 15 meV and high pulse-peak intensities at lower energies. Distribution of the cold neutrons on a moderator viewed surface was studied and found to exhibit an intensity-enhanced region at the fringe part near the premoderator. This rather peculiar distribution suggested that the moderator and the viewed surface must be designed so as to take the full advantage of the brighter region near the premoderator.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.