Abstract

In this article, we describe a new image analysis software that allows rapid segmentation and separation of fluorescently stained cell nuclei using a fast ellipse detection algorithm. Detection time ranged between 1.84 and 3.14 s. Segmentation results were compared with manual evaluation. The achieved over-segmentation rate was 0.11 (0.1 double counts and 0.01 false positive detections), and the under-segmentation rate was of 0.03 over all images. We demonstrate the applicability of the proposed algorithm to automated counting of fluorescent-labeled cell nuclei and to tissue characterization. Moreover, the performance of the proposed algorithm is compared with preexisting automated image analysis techniques described by others.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.