Abstract
The study determines the cost-utility of a unilateral electronic knee prosthesis (C-leg) compared to mechanical alternatives in trans-femoral amputees. For each type of prosthesis, 50 patients, treated in a major Italian centre, were enrolled. Quality adjusted life years (QALYs) were estimated from responses to EuroQol (EQ-5D). Healthcare and social costs were assessed for the estimated life cycle of the technologies (5 years). C-leg was associated with 0.09 more QALYs per patient per year (P = 0.007). For the 5-year period, the incremental cost-utility ratio of C-leg resulted in euro 35,971 per QALY from the healthcare system perspective. If non-healthcare costs and productivity losses are included, the two groups to have similar costs (euro 66,669 vs euro 66,927).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.