Abstract

At Cleveland clinic, an incorrect surgical count triggers Code Rust; a protocol that mandates an intraoperative patient X-ray, staff radiology read, and discussion with the surgeon before the incision is closed. Code Rust calls from November 2014 to December 2022 were retrospectively reviewed. Realtime workflow and operative details of Code Rust cases were analyzed.1277 Code Rusts were identified. Average time from ordering the X-ray to final radiology report was 50 minutes, totalling $2,362,450.00 spent on operating room time. Code Rust was called twice as frequently during urgent or emergent cases, compared to elective. There were more staff in Code Rust rooms compared to non-Code Rust rooms. A foreign body on X-ray was identified in 42/1277 (3.3%) cases. Code Rust is a resource intensive process that is more common in emergent cases that involve multiple staff. While retained foreign bodies are identified in a small percentage of cases, the current system should be revisited to reduce operating time and expense.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.