Abstract

Outcomes for transcatheter pulmonary valve replacement (TC-PVR) and operative pulmonary valve replacement (S-PVR) are excellent. Thus, their respective cost is a relevant clinical outcome. We performed a retrospective cohort study of children and adults who underwent PVR at age ≥ 8 years from January 1, 2011, to December 31, 2013, at 35 centers contributing data to the Pediatric Health Information Systems database to address this question. A propensity score-adjusted multivariable analysis was performed to adjust for known confounders. Secondary analyses of department-level charges, risk of re-admission, and associated costs were performed. A total of 2,108 PVR procedures were performed in 2,096 subjects (14% transcatheter and 86% operative). The observed cost of S-PVR and TC-PVR was not significantly different (2013US $50,030 vs 2013US $51,297; p = 0.85). In multivariate analysis, total costs of S-PVR and TC-PVR were not significantly different (p = 0.52). Length of stay was shorter after TC-PVR (p <0.0001). Clinical and supply charges were greater for TC-PVR (p <0.0001), whereas laboratory, pharmacy, and other charges (all p <0.0001) were greater for S-PVR. Risks of both 7- and 30-day readmission were not significantly different. In conclusion, short-term costs of TC-PVR and S-PVR are not significantly different after adjustment.