Abstract

The risk of falls in people with Multiple Sclerosis (MS) is much greater than that of the general population due to impaired coordination, gait, sensation, muscle tone, strength, and cognition. These MS related falls hamper the day to day living of these individuals and are one of the prime factors aggravating the disease related morbidity. The fear of falling itself may make these individuals more dependent and hinder their professional and leisurely activities. Hence, the significance of identifying individuals who are at risk of falling and instituting preventive counter-measures cannot be overemphasized. Various simple clinical tests and questionnaires have been recommended for this purpose, but are far from ideal.The objective was to find accurate measures to predict a future fall in MS patients. We also aimed to enquire about the prevalence of falls in MS population and its clinical profile which included detailed history about the past falls, Expanded disability status scale (EDSS) scores, Timed 25 foot walk (T25FW) scores, Activities specific balance confidence (ABC) scores, Falls efficacy scale international (FESI) scores, Multiple Sclerosis Walking Scale 12 (MSWS12) questionnaire.This was a prospective cohort study conducted at the Institute of Neurology, Chennai from January 2015 to August 2017. MS patients of any subtype attending Neurology OPD satisfying revised 2010 McDonald criteria were recruited. 134 subjects with MS consented to participate in this study and 113 of them who met the criteria were included. Baseline history was obtained about the number of falls in the previous year. EDSS, T25FW, ABC, FESI, and MSWS12 scores were obtained at the baseline. VEMP and SEP tests were done and the baseline P13/N23 cVEMP latencies, N10 oVEMP latency, and P37 lower limb SEP latency were obtained. These subjects were followed up for one year and were enquired if they had fallen during that period and the number of falls was recorded. Logistic regression models were used to compute the area under receiver operating characteristic curve (AUC) for each variable tested. Pearson correlation coefficients were calculated for each variable with the number of future falls.Among the 113 patients, 72% (n = 81) had one or more falls during follow-up. Among all variables tested P13 cervical VEMP latency had the highest predictive accuracy (AUC = 0.820) followed by N10 ocular VEMP latency (AUC = 0.794) and P37 SEP latency (AUC = 0.732). P13 latency also had the highest correlation coefficient (R = 0.689, R2 = 0.475) with the number of future falls.P13, N10 and P37 latencies were the most accurate in predicting a future fall when compared to clinical measures.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.