Abstract
Corynebacterium diphtheriae still represents a global medical challenge, particularly due to the significant number of individuals susceptible to diphtheria and the emergence of non-toxigenic strains as the causative agents of invasive infections. In this study, we characterized the clinical and microbiological features of what we believe to be the first case of C. diphtheriae infection of a percutaneous nephrostomy catheter insertion site in an elderly patient with a fatal bladder cancer. Moreover, we demonstrated the potential role of adherence, biofilm formation and fibrin deposition traits in C. diphtheriae from the catheter-related infection. Non-toxigenic C. diphtheriae isolated from the purulent discharge (named strain BR-CAT5003748) was identified by the API Coryne system (code 1 010 324) and a multiplex PCR for detection of dtxR and tox genes. Strain BR-CAT5003748 showed resistance to oxacillin, ceftazidime and ciprofloxacin. In experiments performed in vitro, the catheter isolate was classified as moderately hydrophobic and as moderately adherent to polystyrene surfaces. Glass provided a more effective surface for biofilm formation than polystyrene. Micro-organisms adhered to (>1.5 x 10(6) c.f.u.) and multiplied on surfaces of polyurethane catheters. Microcolony formation (a hallmark of biofilm formation) and amorphous accretions were observed by scanning electron microscopy on both external and luminal catheter surfaces. Micro-organisms yielded simultaneous expression of localized adherence-like and aggregative-like (LAL/AAL) adherence patterns to HEp-2 cells. Interestingly, the coagulase tube test resulted in the formation of a thin layer of fibrin embedded in rabbit plasma by the non-toxigenic BR-CAT5003748 strain. In conclusion, C. diphtheriae should be recognized as a potential cause of catheter-related infections in at-risk populations such as elderly and cancer patients. LAL/AAL strains may be associated with virulence traits that enable C. diphtheriae to effectively produce biofilms on catheter surfaces. Biofilm formation and fibrin deposition could have contributed to the persistence of C. diphtheriae at the infected insertion site and the obstruction of the nephrostomy catheter.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.