Abstract

AbstractA corrosion study of API X52 steel was carried out in natural seawater with several concentrations of a corrosion inhibitor (10, 100 and 200 ppm) using a rotating cylinder electrode (RCE) to control the hydrodynamic conditions at environment temperature, atmospheric pressure and 24 h of the exposition time. The rotation speed used was 1000 rpm (turbulent flow). The electrochemical techniques used in the corrosion studies were: linear polarisation resistance (LPR), electrochemical impedance spectroscopy (EIS) and polarisation curves (PCs). The superficial analysis was made using a scanning electron microscope (SEM). The results show a good correlation between electrochemical techniques used. In addition, under turbulent flow, the test solution with 10 ppm had the smallest corrosion rate (CR). It is important to mention that the morphology of the corrosion in all experiments was localised corrosion.