Weld imperfections are likely to arise during any welding process. Due to the enormous number of joints that could result in weld defects, welding process faults could happen. Repair procedures are required to address welding defects. Multiple repairs are required if welding mistakes are made repeatedly. The duplex material used in this study is SA 240 TP 904L. By altering the repair procedure treatment 1x, 3x, 5x, and without repair, the welding process is carried out utilizing the SMAW method and E309L filler. Microstructure testing, ferrite content testing, and 3-electrode cell corrosion are the test techniques used. The relationship between the corrosion rate and the amount of ferrite content was deduced from the test data. The corrosion rate increases as the ferrite content rises due to several repairs.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.