Abstract

to minimize the damage of base metals by the corrosion in this study. Type 304 stainless steel (304SS) and Inconel-600 (I-600) that are major components of the primary coolant system in pressurized water reactor were tested. To improve the integrity of base metal to the corrosion, we tested Ni2+, Fe3+, Cr6+, or Cu2+ by adding in NP solutions as a corrosion inhibitor and found that general and local corrosions were suppressed by the addition of Cu2+ ion. Decontamination performance and corrosion tests for NP(Cu) process with HYBRID (HYdrazine Base Reductive metal Ion Decontamination) process as a multi-step process were carried out and compared with existing processes such as citric-oxalic acid and oxalic acid. Our tests revealed that NP(Cu)-HYBRID process greatly inhibited local corrosions such as pits and Intergranular Attack. Moreover the proposed process was assured by the decontamination performance equivalent to other conventional processes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call