Abstract
The electrochemical behaviour of pure Zn and galvanized steel in solutions simulating the pore solution of carbonated concrete has been studied by means of potentiodynamic polarization tests and polarization resistance measurements. Pure Zn was chosen because it simulates well the behaviour of galvanized steel, yielding more reproducible results. The effect of different degrees of carbonation and the presence of different chloride contents in the simulated pore solutions was investigated. Results show that at a given pH (about 9.5) the corrosion susceptibility of Zn depends on anions concentration (carbonate and bicarbonate). The results obtained in simulated carbonated concrete pore solutions show that with low anion concentration Zn does not passivate while in presence of high levels of carbonate and bicarbonate the corrosion resistance is improved. Besides, the presence of chloride increases the corrosion susceptibility.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.