Abstract
A thorough failure investigation was conducted into a failure of waste heat boiler tubes in a methanol plant to determine the failure mechanism, and contributing factors. The investigation was performed utilizing different characterization techniques, including optical light microscopy, scanning electron microscopy, mechanical testing and chemical analysis techniques. The investigation findings showed that the tubes failure is attributed to corrosion under deposit. Details of the failure’s contributing factors, and recommendations to avoid similar failures, are discussed in this article.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.