Abstract

Before being put to use, a new condenser of 600 MW unit was found corrosion leakage of a large number of 304L stainless steel tubes during the water leakage test. Through field investigation, sampling, chemical composition and mechanical properties test, metallographic analysis, corrosion area surface morphology and micro area component analysis, corrosion reasons were analyzed. The main reason for corrosion is improper installation. Stainless steel tubes were polluted by rain, soil, welding slag during the installation process. Carbon steel members cut the tubes when wore tubes, and was placed in such condition for a too long time. Moreover, the electric current occurred in repair welding with water may accelerate pitting holes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.