Abstract
Health degradation by corrosion of steel in civil engineering is a persistent problem. Structural health monitoring techniques can lead to improve estimates of structural safety and serviceability effectively. The corrosion sensor and the monitoring method have been explored and applied in RC beam's corrosion monitoring. A novel five-electrode corrosion sensor has been developed to provide the platform for corrosion monitoring of the steel bar in concrete beam by electrochemical method. Half-cell potential of the RC beam has been measured to identify the corrosion statues of the steel bar qualitatively. Galvanostatic step method has been used to excite the steel-concrete system and the transient response of the system has been obtained. The data of the transient response has been analyzed by segmented method. Some important electrochemical parameters have been extracted by this method. The results show it is effectively to analyze the data of the transient response by segmented method.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.