Abstract

The corrosion fatigue behavior of epoxy-coated Mg–3Al–1Zn alloy was investigated in air and 3.5 wt% NaCl solution. Epoxy coating as a new method was used to improve the corrosion fatigue property of the material. Results show that the fatigue limit (FL) of the coated specimens is higher than that of the uncoated specimens in 3.5 wt% NaCl solution because of the strengthening and blocking functions of the epoxy coating. The FL of the coated specimens in 3.5 wt% NaCl solution is as high as that in air. It implies that the coated specimens are not as sensitive to the environment as the magnesium alloy. The low tensile strength and the short elongation of the pure epoxy coating lead to that the fatigue crack of the coated specimen is always initiated from the epoxy-coating film. Pores and pinholes accelerate the fatigue crack initiation process. Pinholes are caused by the corrosion reactions between the epoxy coating and the NaCl solution.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.