Abstract

Introduction In this paper, a novel Ti-15Ta-5Zr alloy with α+β stable, homogeneous, biphasic microstructure was synthesized; this alloy revealed very good mechanical properties and hardness and a Young’s modulus of 42.2 GPa, which are more suitable for an implant material than those of other existing implant materials (Ti, Ti-6Al-4V). Experimental The microstructure was identified by scanning electron microscopy (SEM). Electrochemical properties of the interface between new alloy and simulated physiological Ringer-Brown solution were investigated by the potentiodynamic cyclic and linear polarization and electrochemical impedance spectroscopy (EIS). Results and discussion SEM (Fig. 1) image of the chemically etched surface revealed a homogeneous α+β biphasic microstructure showing the characteristic interleaving lamellas of α and β phases. The cyclic potentiodynamic curves in Ringer-Brown solution (Fig. 2) showed the self-passivation of Ti-15Ta-5Zr alloy with a large constant current domain that indicates the absence of the electron transfer reactions and the existence of the ion transfer reactions, namely, the constant thickening of the oxide layer, according with the high field mechanism. The curve for Ti characterized by a slow increase of the passive current density with the applied potential suggests that its native passive film seems to dissolve and repassivate. These behavior differences between Ti and Ti-15Ta-5Zr alloy are due to the alloying elements Ta and Zr, which stabilize, reinforce the passive film on the new alloy surface. Alloy corrosion, Ecorr potentials have more electropositive value and passive current densities, ip are lower than those of Ti (Table 1) as result of the more compact, thicker, resistant passive film existing on the Ti-15Ta-5Zr alloy surface, that contains both protective TiO2 and Ta2O5 and ZrO2 oxides. The alloy corrosion current densities, icorr and rates, Vcorr are lower (of about 70 times smaller) than those of Ti, proving a more protective passive film on the alloy surface. The alloy polarization resistances, Rpreached higher values (about ten times higher) than those of Ti, fact that represents a very corrosion resistant material.Table 1. Main electrochemical parameters in Ringer-Brown solution MaterialEcorr (mV)icorr (µA/cm2)Vcorr (µm/y)ip (µA/cm2)Rp (kΩ.cm2) Ti-2503.89044.110.529 Ti-15Ta-5Zr-2100.0550.631.12250 The Nyquist plots (Fig. 3a) exhibited open arches, demonstrating capacitive behaviour, namely, a passive film with dielectric properties; the bigger diameters and impedance values for the alloy describe a more insulating, thicker, protective passive film on its surface. Bode phase spectra (Fig. 3b) displayed two phase angles; the higher phase angles recorded for the new alloy denote a nobler passive behaviour, a more stable passive state. These phase angles suggest a passive film with two layers: for the higher phase angle corresponds a barrier, compact, inner layer and the lower phase angle indicates a less protective, porous, outer layer. The open circuit potentials of the new Ti-15Ta-5Zr alloy shifted to nobler values in time; this behavior indicates the film thickening that confers high protection to alloy. SEM micrograph evinced (Fig. 4) some depositions on the alloy surfaces after 2000 immersion hours in Ringer-Brown solution; it is a continuous layer formed by globular nanocrystals with the diameter of about 2-3 µm, with interwoven texture in a porous feature. EDX elemental analysis (Fig. 4) detected the presence of calcium, phosphorus and oxygen, namely calcium phosphate, a precursor of the hydroxyapatite, the major inorganic component of the human bone. Therefore, the alloy surface represents a suitable support for the adhesion of the bone cells. Conclusions Main electrochemical parameters attested a nobler behaviour and lower corrosion rates, proving more resistant passive film on the alloy surface (in comparison with Ti) that is reinforced, stabilized by the very protective oxides of the alloying elements Ta and Zr. The new alloy represents an advanced alloy in the domain of the non-toxic, non-allergenic ternary implant alloys.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.