Abstract

Carbon steel pipelines are widely used for injection of sea and other waters into oil and gas wells so as to increase the rate of recovery, particularly from mature fields. Internal corrosion usually is mild. However, cases of very aggressive channelling corrosion along the bottom of the pipeline have been observed. Practical experience and anecdotal observations have attributed this to microbiologically influenced corrosion even though extensive use is made of preventative measures including biocides, oxygen scavengers, corrosion and scale inhibitors, and pipeline pigging. Interpretation of data and observations for five water injection pipelines, made available by industry, indicate that microbiologically influenced corrosion may play a part in causing channelling corrosion but that the most likely cause is under-deposit corrosion under pipe debris that settles during periods of pipeline shut-downs and low water velocity.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.