As an important part of the guyed device of cable stayed tower, guyed rod plays a key role of preventing transmission tower from tilting and toppling. In this paper, the corroded guyed rod of 500kV transmission tower was investigated by means of macro-morphology inspection, chemical composition analysis, scanning electron micrograph analysis, microstructure analysis and energy spectrum analysis. The result showed that high content of corrosive sulfate in the soil near the leg of transmission tower was the main cause of corrosion of the guyed rod.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.