Abstract

Of the two types of rating indices for the heavy weight floor impact sound insulation, the method of utilizing a rubber ball impact source combined with A-weighted sound level and the method utilizing a tire impact source combined with L-rating curve, the advantage of the former has been reported. In order to extend the advantage, the possibility was studied of estimating the rating utilizing the rubber ball impact source, based on the measurement results utilizing the tire impact source, especially for the case of a double leaf wooden floor. The correlation between the indices is not high enough to estimate one of them directly from the other with an accuracy not incorrectly estimating the rating grade of 5dB step. The use of predictor variables, such as the special specifications of the double leaf wooden floor, for example, the use of sound insulation sheet, and the floor impact sound levels in the 31.5-Hz, 63-Hz and 125-Hz bands, is possibly able to increase the accuracy. Three principal types of multiple regression equation were derived through the analysis of measurement results in existing residential buildings.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.