Abstract

Experimental results of the saturated-flow boiling critical heat flux (CHF) in microchannels for both multi- and single-channel configurations were obtained from the literature. The collected database contains 629 data points, covering five halogenated refrigerants, nitrogen, and water, for a wide range of operational conditions, and different microchannel dimensions. The whole database was analyzed by using five empirical correlations to verify their respective accuracies. However, none of the existing correlations could predict the entire database precisely. A saturated CHF correlation was proposed by using boiling number, length-to-diameter ratio, and exit quality. Combining with the energy balance equation, the new correlation can predict the overall microchannel database accurately on the whole. It predicts almost 97.0% of the non-aqueous data (except R12 data points located in the macro-scale region) and 94.0% of the water data within the ±30% error band.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.