Abstract

Abstract. The general microbial quality of drinking water is normally monitored by heterotrophic plate counts (HPC). This method has been used for more than 100 years and is recommended in drinking water guidelines. However, the HPC method is handicapped because it is time-consuming and restricted to culturable bacteria. Recently, rapid and accurate detection methods have emerged, such as adenosine tri-phosphate (ATP) measurements to assess microbial activity in drinking water, and flow cytometry (FCM) to determine the total cell concentration (TCC). It is necessary and important for drinking water quality control to understand the relationships among the conventional and new methods. In the current study, all three methods were applied to 200 drinking water samples obtained from two local buildings connected to the same distribution system. Samples were taken both on normal working days and weekends, and the correlations between the different microbiological parameters were determined. TCC in the samples ranged from 0.37–5.61×105 cells/ml, and two clusters, the so-called high (HNA) and low (LNA) nucleic acid bacterial groups, were clearly distinguished. The results showed that the rapid determination methods (i.e., FCM and ATP) correlated well (R2=0.69), but only a weak correlation (R2=0.31) was observed between the rapid methods and conventional HPC data. With respect to drinking water monitoring, both FCM and ATP measurements were confirmed to be useful and complimentary parameters for rapid assessing of drinking water microbial quality.

Highlights

  • For more than 100 years, microbial characterization of drinking water has relied on heterotrophic plate counts (HPC) (Sartory, 2004)

  • All three methods were applied to 200 drinking water samples obtained from two local buildings connected to the same distribution system

  • The results showed that the rapid determination methods (i.e., flow cytometry (FCM) and adenosine tri-phosphate (ATP)) correlated well (R2=0.69), but only a weak correlation (R2=0.31) was observed between the rapid methods and conventional HPC data

Read more

Summary

Introduction

For more than 100 years, microbial characterization of drinking water has relied on heterotrophic plate counts (HPC) (Sartory, 2004). This method is used world-wide for monitoring drinking water quality in the distribution network and for assessing the efficacy of treatment steps (Allen et al, 2004; Reasoner and Geldreich, 1985). In Switzerland the statutory limit of HPC bacteria has been set to 20 colony forming units per ml (CFU/ml) after treatment, and to 300 CFU/ml within the distribution system (HyV, 2006; SLMB, 2000), which concurs with world-wide accepted guidelines (WHO, 2006).

Sampling
Flow cytometric total cell counts measurements
Overview of the measurements with different methods
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call