Abstract

In this work an adapted bench-scale Mass Loss Calorimeter (MLC) device is used to measure HRR for forest fuels. The MLC has the same heating unit as a standard cone calorimeter, but a) the physical basis to measure HRR in a MLC (by using a calibrated thermopile) is different than the one used in the standard cone calorimeter (oxygen consumption method) and b) the MCL does not have a unit to measure the concentration of the gases produced during the combustion. Although the concentration values are not essential to measure the HRR curves, their knowledge is of great interest to characterize the combustion process and the combustion efficiency. In this sense, a Fourier transform based spectroradiometer (FTIR) has been adapted to the MLC in a short open-path configuration to measure “in situ” the concentration of carbon monoxide and dioxide and water vapour, nearly simultaneous to the measurement of the HRR values. This simultaneity in both types of measurements allows one to find correlations between different variables. These correlations would help to make predictions on unknown variables in the framework of fire models.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.