Abstract

Hyperpolarized (HP) MRI provides the means to monitor lactate metabolism noninvasively in tumours. Since -lactate signal levels obtained from HP imaging depend on multiple factors, such as the rate of substrate delivery via the vasculature, the expression level of monocarboxylate transporters (MCTs) and lactate dehydrogenase (LDH), and the local lactate pool size, the interpretation of HP metabolic images remains challenging. In this study, ex vivo tissue extract measurements (i.e., NMR isotopomer analysis, western blot analysis) derived from an MDA-MB-231 xenograft model in nude rats were used to test for correlations between the in vivo data and the ex vivo measures. The lactate-to-pyruvate ratio from HP MRI was strongly correlated with [1- ]lactate concentration measured from the extracts using NMR (R = 0.69, p 0.05), as well as negatively correlated with tumour wet weight (R = 0.60, p 0.05). In this tumour model, both MCT1 and MCT4 expressions were positively correlated with wet weight ( = 0.78 and 0.93, respectively, p 0.01). Lactate pool size and the lactate-to-pyruvate ratio were not significantly correlated.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.