Abstract

Functional electric stimulation is a new method for dynamic rehabilitation of paralyzed muscles. The output of such prosthetic devices needs to be modulated by some index of the muscle movement. In facial paralysis a measure of the muscle contractions of the normal contralateral side seems to be an appropriate input. In the rabbit, we simultaneously measured the compound action potential of the buccal branch of the facial nerve, the electromyogram of the zygomaticus major muscle, and the muscle twitch tension through strain gauge. The compound action potential, electromyogram, and strain gauge each had a sigmoidal relationship to stimulus intensity. The compound action potential peak-to-peak amplitude was found to have a linear correlation to the peak twitch tension of the corresponding facial muscle. The electromyogram response, although more variable, also had a linear correlation with muscle contraction. The possibility of predicting the contraction of facial muscles before they actually occur is discussed in the context of available and future functional electric rehabilitation models.