The effects of plasma damage on dielectric reliability were studied using voltage ramp stress experiments. Altering ramp rates allowed us to identify the main mechanisms for failure, namely intrinsic and metal catalyzed failure. Failure mechanisms are identified using ∂ln (tBD)/∂ln (R) trends for pristine and plasma damaged SiCOH films. Failure dynamics are discussed for 7% and 25% porous SiCOH films. O2 plasma treatment was found to lower the breakdown strength of 7% SiCOH from 79.5 V to 67.1 V at low ramp rates (0.01 V/s), and from 135.7 V to 109.3 V at fast ramp rates (20 V/s). The breakdown strength of 25% SiCOH films was enhanced from 41.0 V to 55.4 V after plasma treatment at slow ramp rates. However, at fast ramp rates, the plasma treatment lowered the breakdown voltage from 112.0 V to 99.7 V. The enhancement in breakdown strength for highly porous samples under slow ramp rates is attributed to film densification upon plasma treatment, while the deterioration at fast ramp rates is associated with the generation of defects catalyzing dielectric failure.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.